ppk2-mcp
MCP server for Nordic Semiconductor's Power Profiler Kit II (PPK2). Provides 12 tools for discovering, connecting, configuring, and measuring current draw directly from Claude Code or Claude Desktop.
Features
- Discover PPK2 devices on USB
- Connect with automatic calibration loading
- Configure source/ampere mode and supply voltage
- Measure current at ~100 kHz native sample rate
- Log raw measurements to timestamped CSV files
- Inspect saved logs without leaving the conversation
Requirements
- Python 3.10+
- Nordic Semiconductor PPK2 hardware
- USB connection to PPK2
Quick Start
git clone https://github.com/Ultrahuman-tech/ppk2-mcp.git
cd ppk2-mcp
python3 -m venv .venv
source .venv/bin/activate
pip install -r requirements.txt
Then configure your MCP client (see below).
Configuration
Claude Code
Add to ~/.claude.json under mcpServers:
{
"mcpServers": {
"ppk2": {
"command": "/path/to/ppk2-mcp/.venv/bin/python3",
"args": ["/path/to/ppk2-mcp/ppk2_server.py"],
"type": "stdio"
}
}
}
Claude Desktop
Add to claude_desktop_config.json:
{
"mcpServers": {
"ppk2": {
"command": "/path/to/ppk2-mcp/.venv/bin/python3",
"args": ["/path/to/ppk2-mcp/ppk2_server.py"]
}
}
}
Replace /path/to/ppk2-mcp with the actual clone location.
Tools Reference
| Tool | Description | |------|-------------| | list_devices | Scan USB for connected PPK2 devices | | connect | Connect to a PPK2 and load calibration (returns session ID) | | disconnect | Disconnect, stop measurement, power off DUT | | set_mode | Set operating mode: source (PPK2 powers DUT) or ampere (external power) | | set_voltage | Set supply voltage in mV (source mode only, 800-5000 mV) | | power_control | Toggle DUT power on/off | | get_session_info | Show current session state | | start_measuring | Begin continuous current measurement | | stop_measuring | Stop continuous measurement | | measure | Atomic: start, collect for N seconds, stop, save CSV, return stats | | list_logs | List saved measurement CSV files | | get_log | Read a saved log file (metadata + first N rows) |
Typical Workflow
list_devices → find PPK2 on USB
connect → get session_id
set_mode "source" → PPK2 supplies power
set_voltage 3300 → 3.3V to DUT
power_control "on" → power up the device
measure 5.0 → capture 5 seconds of current data
disconnect → clean up
Logs
Raw measurement data is saved to the logs/ directory as timestamped CSV files. Each file contains:
- Comment header with metadata (date, duration, mode, voltage, sample count, sample rate)
- CSV data columns:
sample_idx,current_ua(optionallydigitalfor digital channels)
Example: ```
PPK2 Raw Measurement Log
Date: 2025-02-18 19:57:00
Duration: 2.01s
Mode: source
Voltage: 3300 mV
Samples: 200,544
Sample Rate: 99,773 sps
sample_idx,current_ua 0,1523.45 1,1518.22 ... ```
Known Issues
- Stale serial buffer on reconnect: After a previous session crashes or is interrupted, the PPK2's serial buffer may contain leftover binary measurement data. The server handles this automatically by flushing the buffer before reading calibration data.
- Metadata decode errors: The upstream
ppk2-apilibrary can crash on binary noise in the serial buffer. This server includes a built-in patch (latin-1 fallback) so no manual library edits are needed.
License
MIT - see LICENSE.